Our range of products include laboratory fume hood, bench top fume hood, lbs- fh-44 laboratory fume hood, laboratory chemical fume hood, double entry fume hood and laboratory fume exhaust hoods.
Being a good name in the industries, we are engaged manufacturing, exporting & supplying a distinguished range of Laboratory Fume Hood. Our offered fume hood is intricately designed under the vigilance of skilled professionals using quality tested raw material and sophisticated technology in line with the international quality standards. Clients can avail this range in various designs, shapes and sizes at market leading price within given period of time.
Features:
Smooth finish
Unique look
Innovative design
Models:
Model
LBS-FH-22
LBS-FH -32
LBS-FH -42
LBS-FH -52
LBS-FH -62
Working Size
2’x2’x2’
3’x2’x2’
4’x2’x2’
5’x2’x2’
6’x2’x2’
Baffle:
Removable plates incorporated into the rear or top of the work chamber to form a plenum between the work chamber and the exhaust duct connection to promote uniform scavenging of fume and the point of discharge.
Exhaust System:
All exhaust air ductwork, fan and associated equipment installed at the point of connection to the fume hood and the point of discharge.
Face Velocity:
The velocity of the air passing through the work opening of the fume hood measured in the plane of the sash. Measured in feet per minute (fpm), or litres per second.
Make-up Air:
Air needed to replace the air exhausted from a room by the fume hood and other ventilation devices.
Plenum:
A low-velocity chamber used to distribute static pressure (from the fan in the system) throughout its interior
Sash:
A transparent safety screen in the work opening of the fume hood, which can be positioned between the operator and the work chamber for protection. The opening can be adjusted vertically to vary the size of the opening and control the face velocity of air into the fume hood.
Sash Opening:
The dimension of the opening in the direction of the sash movement
We manufacture an extensive range of Bench Top Fume Hood that is widely used for the removal of gas, vapors and chemical mist. We offer these in order to meet the emission standards for safety to health and environment. These are constructed with utmost precision and are highly efficient.
Features:
Conventional Constant Volume
Majority air enters through the opening of sash
Exhaust volume remains constant
Constructed with utmost precision
Apt for general low hazard applications
Low-pressure drop
Highly efficient
Maintenance free
Minimum energy requirement
Model
LBS-BFH-22
LBS-BFH -32
LBS-BFH -42
LBS-BFH -52
LBS-BFH -62
Working Size
2’x2’x2’
3’x2’x2’
4’x2’x2’
5’x2’x2’
6’x2’x2’
Request Callback
Yes! I am Interested
LBS- FH-44 Laboratory Fume Hood
Get Best Quote
Approx. Price: Rs 53,880 / PieceGet Latest Price
Product Details:
Minimum Order Quantity
1 Piece
Usage/Application
Laboratory
Brand
Labsol
Model Name/Number
LBS- FH-44
Shape
Rectangular
Temperature Range
0-90 degree
Product Type
Bench-top
Power
220V
Voltage
50Hz
Socket
3-pin plug
Utility Service
Vacuum, Pp Sink, Gas
Weight
120 Kg
Exhaust
Blower
Air Velocity
90-120 fpm
Motor Power
1 HP
Number Of Lights
1
Features
Standard
Automation Type
Semi-Automatic, Automatic
Motor
Crompton
Surface Finish
Power coated
Lighting
LED tube light
Grade Standard
A-class
We are offering for our valued client’s quality approved Fume Hood. This is designed in accordance with the set industry standards at our end. Offered fume hood can be accessed in varied sizes and dimensions for applications in different industries. Features:
Excellent strength
Non-corrosive
Easy installation
Baffle:
Removable plates incorporated into the rear or top of the work chamber to form a plenum between the work chamber and the exhaust duct connection to promote uniform scavenging of fume and the point of discharge.
Exhaust System:
All exhaust air ductwork, fan and associated equipment installed at the point of connection to the fume hood and the point of discharge.
Face Velocity:
The velocity of the air passing through the work opening of the fume hood measured in the plane of the sash. Measured in feet per minute (fpm), or litres per second.
Make-up Air:
Air needed to replace the air exhausted from a room by the fume hood and other ventilation devices.
Plenum:
A low-velocity chamber used to distribute static pressure (from the fan in the system) throughout its interior.
Sash:
A transparent safety screen in the work opening of the fume hood, which can be positioned between the operator and the work chamber for protection. The opening can be adjusted vertically to vary the size of the opening and control the face velocity of air into the fume hood.
Sash Opening:
The dimension of the opening in the direction of the sash movement
Request Callback
Additional Information:
Item Code: LBS-FH-44
Delivery Time: 3-4 weeks
Packaging Details: Wooden packing
Yes! I am Interested
Laboratory Chemical Fume Hood
Get Best Quote
Approx. Price: Rs 50,000 / PieceGet Latest Price
Product Details:
Country of Origin
Made in India
Usage/Application
Laboratory
Automation Type
Automatic
Material
Stainless Steel
Voltage
220 V
Frequency
50 Hz
Phase
Single Phase
We are engaged in offering a wide range of Laboratory Chemical Fume Hood to our clients. Our range of all products is widely appreciated by our clients.
Request Callback
Yes! I am Interested
Double Entry Fume Hood
Get Best Quote
Approx. Price: Rs 65,000 / PieceGet Latest Price
Product Details:
Metal Type
Steel
Material
Metal
Type
Laboratory Furniture
Baffle
1 section
Entry
Double
The company is well known in the market for the supply and the manufacture of a wide range of Double Entry Fume Hood which are engaged in the protection of laboratory from the various acid fumes and they offer a high performance to the customers. These products are highly exported to the customers all over the globe and they have been priced at very reasonable rates in the market. These products are easy to operate and they are delivered to the customers on time. Features Include:
Welded superstructure for structural rigidity and design flexibility to accommodate custom hood sizes and features
Single top exhaust baffle
Wide Post (flat front) side post design can accept up to two electrical and four plumbing fixtures on one post of each sash
Full frame, stainless steel vertical sash with integral stainless steel finger pull
Stainless steel sash guides, duct collar
Sash/counterweight pulley system utilizing six 2 ½”-diameter pulleys for smooth, dependable operation
Vapor-proof incandescent light fixture (bulb not included)
Optional equipment includes:
Liner material ¼” composite stone; ¼” white epoxy-coated composite stone; ¼” poly-resin all non-asbestos
Sash interlock automatically locks one sash closed when other sash is open
Electrical switches and receptacles. Also explosion-proof lighting and fixtures available
Remote-controlled plumbing fixtures, with chrome or color-coded outlets. Pre-piped hard copper with soldered joints
Sash stop
Ceiling enclosure
Air velocity monitor/alarm
Countertops-epoxy, phenolic, stainless steel
Cabinets-complete line of metal laboratory casework, including hood base, acid storage and flammable storage cabinets
Blowers-selected to match hood and ductwork configuration and application
Model
LBS-BFH-22
LBS-BFH -32
LBS-BFH -42
LBS-BFH -52
LBS-BFH -62
Working Size
2’x2’x2’
3’x2’x2’
4’x2’x2’
5’x2’x2’
6’x2’x2’
Request Callback
Yes! I am Interested
Laboratory Fume Exhaust Hoods
Get Best Quote
Approx. Price: Rs 40,000 / PieceGet Latest Price
Product Details:
Material
Stainless Steel
Brand
Labsol
Size
5'x2'x2' ft
Panel Thickness
6 mm
Panel Material
Toughened Glass
Duct Material
PP, PVC, HDPE
We are offering for our valued client’s quality approved Fume Hood. This is designed in accordance with the set industry standards at our end. Offered fume hood can be accessed in varied sizes and dimensions for applications in different industries. Features:
Excellent strength
Non-corrosive
Easy installation
Baffle:
Removable plates incorporated into the rear or top of the work chamber to form a plenum between the work chamber and the exhaust duct connection to promote uniform scavenging of fume and the point of discharge.
Exhaust System:
All exhaust air ductwork, fan and associated equipment installed at the point of connection to the fume hood and the point of discharge.
Face Velocity:
The velocity of the air passing through the work opening of the fume hood measured in the plane of the sash. Measured in feet per minute (fpm), or litres per second.
Make-up Air:
Air needed to replace the air exhausted from a room by the fume hood and other ventilation devices.
Plenum:
A low-velocity chamber used to distribute static pressure (from the fan in the system) throughout its interior.
Sash:
A transparent safety screen in the work opening of the fume hood, which can be positioned between the operator and the work chamber for protection. The opening can be adjusted vertically to vary the size of the opening and control the face velocity of air into the fume hood.
Sash Opening:
The dimension of the opening in the direction of the sash movement
Request Callback
Yes! I am Interested
Walk In Fume Hood
Get Best Quote
Approx. Price: Rs 75,000 / PieceGet Latest Price
Product Details:
Minimum Order Quantity
1 Piece
Brand
Labsol
Material
Stainless Steel
Country of Origin
Made in India
Type
Laboratory Furniture
Baffle
3 section
Fixture
2 or 4 inxh
Based on the skills of our adroit professionals and creative workers, we bring forth an extensive range of Walk-In Fume Hood. Owing to features like durability and easy installation, the offered range is extensively demanded in various industries. A team of our skilled professionals, with a wide experience manufacture the offered fume hoods using high grade raw material and modish technology. The offered fume hoods are available with us in various sizes, designs and other related specifications.
Features:
Excellent finish
Optimum strength
Anti corrosive
Other Details:
Welded superstructure for structural rigidity and design flexibility to contain large equipment and conveyances
Three-piece baffle system with three adjustable dampers to regulate lighter- and heavier-than-air gases
Airfoil around top and sides of sash opening, with electrical fixtures and plumbing controls mounted on bias surface
Bypass grill with adjustable louvers to control bypass air volume
Two independent, full-framed, stainless steel vertical sash with integral stainless steel finger pulls
Stainless steel sash guides, duct collar
Sash/counterweight pulley system utilizing four 2 ½”-diameter pulleys for one-finger sash movement; full-width counterweight featuring “Tilt-Lock” for additional safety and durability
Vapor-proof fluorescent light fixture (bulbs not included)
We are among one of the leading suppliers of Portable Cleanroom. Our mobile and portable cleanrooms have softwall curtains, strip doors and built-in lighting and filters. Best of all these cleanrooms are on wheels. Roll the portable cleanroom to wherever you need it in your manufacturing facility, and you’ll immediately create a quality-controlled environment with low particle counts.
Based on the skills of our adroit professionals and creative workers, we bring forth an extensive Ductless Fume Hood. Owing to features like dimensional accuracy, durability and easy installation, the offered fume hoods are extensively demanded in the market. A team of our adept professionals with hard-earned experience manufacture the offered range using high-grade raw material and the latest technology. Our client can avail these fume hoods from us at market leading prices.
Features:
All natural polypropylene construction seamless design eliminates potential for rust
Chemical resistance with integral spill tray for high volume containment
Baffle promotes an even airflow pattern and provides exceptional capture capability
Constant monitoring and adjustment of face velocity to user preset value
Removable high-temperature flame retardant Trespa base